Category: Integrated Circuit (IC)
Use: The INA126UG4 is a precision instrumentation amplifier designed for accurate signal amplification in various applications.
Characteristics: - High accuracy - Low noise - Low power consumption - Wide input voltage range - Rail-to-rail output swing capability
Package: SOIC (Small Outline Integrated Circuit)
Essence: The INA126UG4 is an essential component in electronic circuits that require precise amplification of small signals.
Packaging/Quantity: The INA126UG4 is typically sold in reels containing 250 units.
The specifications of the INA126UG4 include:
The INA126UG4 has the following pin configuration:
The key functional features of the INA126UG4 are as follows:
Advantages: - High accuracy and precision - Low noise performance - Wide operating temperature range - Versatile supply voltage options - Suitable for low-power applications
Disadvantages: - Limited output current capability - Relatively higher cost compared to some alternatives
The INA126UG4 operates based on the principle of differential amplification. It amplifies the voltage difference between the IN+ and IN- inputs, while rejecting common mode signals. The amplified output is then available at the OUT pin.
The INA126UG4 finds applications in various fields, including:
Some alternative models that can be considered as substitutes for the INA126UG4 are:
These alternatives offer similar functionality and can be chosen based on specific requirements and cost considerations.
Word count: 345 words
Question: What is the typical supply voltage range for INA126UG4?
Answer: The typical supply voltage range for INA126UG4 is ±2.25V to ±18V.
Question: What is the input offset voltage of INA126UG4?
Answer: The input offset voltage of INA126UG4 is typically 50µV.
Question: Can INA126UG4 be used in single-supply applications?
Answer: Yes, INA126UG4 can be used in single-supply applications with proper biasing.
Question: What is the gain bandwidth product of INA126UG4?
Answer: The gain bandwidth product of INA126UG4 is typically 800kHz.
Question: Is INA126UG4 suitable for bridge sensor applications?
Answer: Yes, INA126UG4 is suitable for bridge sensor applications due to its high input impedance and low noise.
Question: What is the common-mode rejection ratio (CMRR) of INA126UG4?
Answer: The CMRR of INA126UG4 is typically 100dB.
Question: Can INA126UG4 be used in medical instrumentation?
Answer: Yes, INA126UG4 is commonly used in medical instrumentation for its precision and low noise characteristics.
Question: What is the maximum input offset voltage drift of INA126UG4?
Answer: The maximum input offset voltage drift of INA126UG4 is typically 0.5µV/°C.
Question: Does INA126UG4 require external compensation?
Answer: No, INA126UG4 has internal compensation and does not require external compensation components.
Question: What is the recommended operating temperature range for INA126UG4?
Answer: The recommended operating temperature range for INA126UG4 is -40°C to +85°C.