Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
INA126U/2K5

INA126U/2K5

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Instrumentation Amplifier
  • Characteristics: High precision, low noise, high common-mode rejection ratio
  • Package: SOIC (Small Outline Integrated Circuit)
  • Essence: The INA126U/2K5 is a precision instrumentation amplifier designed for accurate signal amplification in various applications.
  • Packaging/Quantity: Available in reels of 2500 units

Specifications

  • Supply Voltage: ±2.25V to ±18V
  • Input Offset Voltage: 50µV (maximum)
  • Input Bias Current: 1nA (maximum)
  • Gain Bandwidth Product: 1MHz (typical)
  • Common-Mode Rejection Ratio: 120dB (typical)
  • Operating Temperature Range: -40°C to +85°C

Pin Configuration

The INA126U/2K5 has a total of 8 pins arranged as follows:

```


| | | U | |___________|

Pin Configuration: 1. V+ (Positive Power Supply) 2. REF (Reference Voltage) 3. RG (Gain Resistor) 4. IN- (Inverting Input) 5. IN+ (Non-Inverting Input) 6. V- (Negative Power Supply) 7. OUT (Output) 8. NC (No Connection) ```

Functional Features

  • High input impedance
  • Low output impedance
  • Adjustable gain through external resistor
  • Wide supply voltage range
  • Excellent linearity and accuracy
  • Low power consumption

Advantages and Disadvantages

Advantages: - High precision amplification - Low noise performance - Wide operating temperature range - Versatile application possibilities

Disadvantages: - Limited availability in certain package options - Requires external components for proper operation

Working Principles

The INA126U/2K5 is based on the principle of an instrumentation amplifier. It amplifies small differential input signals while rejecting common-mode noise. The gain can be adjusted by selecting an appropriate value for the external gain resistor (RG). The device operates by using a combination of operational amplifiers and precision resistors to achieve high accuracy and performance.

Detailed Application Field Plans

The INA126U/2K5 finds applications in various fields, including:

  1. Biomedical instrumentation: ECG (Electrocardiogram), EEG (Electroencephalogram), EMG (Electromyography)
  2. Industrial process control: Pressure and temperature measurement
  3. Strain gauge amplification: Load cells, force sensors
  4. Data acquisition systems: Bridge amplification, sensor signal conditioning
  5. Test and measurement equipment: Signal amplification, precision instrumentation

Detailed and Complete Alternative Models

  1. AD620: Instrumentation Amplifier with similar specifications
  2. INA128: Precision Instrumentation Amplifier with higher gain bandwidth product
  3. AD8221: Low power Instrumentation Amplifier with rail-to-rail inputs

These alternative models offer similar functionality and can be considered as substitutes for the INA126U/2K5 depending on specific requirements.

Word count: 366 words

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací INA126U/2K5 v technických řešeních

  1. Question: What is the typical application of INA126U/2K5?
    Answer: The INA126U/2K5 is commonly used for precision instrumentation amplification in various technical solutions.

  2. Question: What are the key features of INA126U/2K5?
    Answer: INA126U/2K5 features low offset voltage, low noise, high common-mode rejection ratio (CMRR), and wide supply voltage range.

  3. Question: How can INA126U/2K5 be used in strain gauge measurements?
    Answer: INA126U/2K5 can be configured as a differential amplifier to accurately measure small changes in resistance from strain gauges.

  4. Question: Can INA126U/2K5 be used in medical instrumentation applications?
    Answer: Yes, INA126U/2K5 is suitable for medical instrumentation due to its high precision and low noise characteristics.

  5. Question: What is the recommended power supply voltage for INA126U/2K5?
    Answer: The recommended power supply voltage range for INA126U/2K5 is typically ±2.25V to ±18V.

  6. Question: How does INA126U/2K5 handle common-mode signals?
    Answer: INA126U/2K5 has a high CMRR, allowing it to reject common-mode signals and amplify the differential input signal accurately.

  7. Question: Can INA126U/2K5 be used in bridge sensor applications?
    Answer: Yes, INA126U/2K5 is well-suited for amplifying signals from bridge sensors such as pressure or load cells.

  8. Question: What is the input impedance of INA126U/2K5?
    Answer: The input impedance of INA126U/2K5 is typically 10^12 ohms, making it suitable for high-impedance sensor interfaces.

  9. Question: Is there a specific layout consideration when using INA126U/2K5?
    Answer: It is important to follow good PCB layout practices to minimize noise and ensure stability when using INA126U/2K5.

  10. Question: Can INA126U/2K5 be used in industrial control systems?
    Answer: Yes, INA126U/2K5 can be employed in industrial control systems for precise signal amplification and measurement.