Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-50-G-U-M12-4.5OVP-000-000

P51-50-G-U-M12-4.5OVP-000-000

Product Category: Industrial Sensor

Basic Information Overview:

  • Category: Industrial Sensor
  • Use: This sensor is designed for industrial applications to measure pressure and provide accurate data for process control and monitoring.
  • Characteristics: The P51-50-G-U-M12-4.5OVP-000-000 sensor features high precision, robust construction, and compatibility with various industrial environments.
  • Package: The sensor comes in a durable housing with a waterproof M12 connector for easy installation and protection against harsh industrial conditions.
  • Essence: The essence of this sensor lies in its ability to accurately measure pressure and transmit the data reliably for industrial processes.
  • Packaging/Quantity: Each package contains one P51-50-G-U-M12-4.5OVP-000-000 sensor.

Specifications:

The P51-50-G-U-M12-4.5OVP-000-000 sensor has the following specifications: - Pressure Range: 0-50 psi - Output: 4-20 mA - Overpressure: 2x rated pressure - Electrical Connection: M12 Connector - Operating Temperature: -40°C to 85°C - Protection Rating: IP67

Detailed Pin Configuration:

The detailed pin configuration of the P51-50-G-U-M12-4.5OVP-000-000 sensor is as follows: - Pin 1: Power Supply (+) - Pin 2: Power Supply (-) - Pin 3: Signal Output - Pin 4: Not Connected

Functional Features:

The functional features of the P51-50-G-U-M12-4.5OVP-000-000 sensor include: - Accurate pressure measurement - Robust construction for industrial use - Reliable data transmission - Easy installation with M12 connector

Advantages and Disadvantages:

Advantages: - High precision measurement - Robust construction for industrial environments - Waterproof M12 connector for easy installation - Wide operating temperature range

Disadvantages: - Limited pressure range (0-50 psi) - Requires compatible interface for data interpretation

Working Principles:

The P51-50-G-U-M12-4.5OVP-000-000 sensor operates on the principle of strain gauge technology, where the applied pressure causes deformation in the sensing element, leading to a change in electrical resistance. This change is then converted into a proportional 4-20 mA output signal.

Detailed Application Field Plans:

The P51-50-G-U-M12-4.5OVP-000-000 sensor is suitable for various industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control and monitoring - Industrial machinery

Detailed and Complete Alternative Models:

Some alternative models to the P51-50-G-U-M12-4.5OVP-000-000 sensor include: - P51-100-G-U-M12-4.5OVP-000-000 (100 psi range) - P51-30-G-U-M12-4.5OVP-000-000 (30 psi range) - P51-50-G-U-M18-4.5OVP-000-000 (M18 connector)

This completes the entry for the P51-50-G-U-M12-4.5OVP-000-000 sensor, providing comprehensive information about its category, basic overview, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-50-G-U-M12-4.5OVP-000-000 v technických řešeních

  1. What is the application of P51-50-G-U-M12-4.5OVP-000-000?

    • The P51-50-G-U-M12-4.5OVP-000-000 is commonly used as a pressure sensor in various technical solutions.
  2. How does P51-50-G-U-M12-4.5OVP-000-000 work?

    • This sensor operates by converting pressure into an electrical signal, which can be utilized for monitoring and control purposes.
  3. What are the typical industries that use P51-50-G-U-M12-4.5OVP-000-000?

    • Industries such as automotive, aerospace, industrial manufacturing, and HVAC often incorporate this sensor into their systems.
  4. What is the pressure range of P51-50-G-U-M12-4.5OVP-000-000?

    • The pressure range of this sensor is 0 to 50 psi, making it suitable for a wide range of applications.
  5. Can P51-50-G-U-M12-4.5OVP-000-000 be used in harsh environments?

    • Yes, this sensor is designed to withstand harsh environmental conditions, including temperature variations and exposure to certain chemicals.
  6. What output signals does P51-50-G-U-M12-4.5OVP-000-000 provide?

    • It typically provides analog voltage or current output signals, depending on the specific model and configuration.
  7. Is calibration required for P51-50-G-U-M12-4.5OVP-000-000?

    • Yes, periodic calibration is recommended to ensure accurate and reliable performance over time.
  8. Can P51-50-G-U-M12-4.5OVP-000-000 be integrated with digital control systems?

    • Yes, it can be integrated with digital control systems through appropriate signal conditioning and interface modules.
  9. What are the mounting options for P51-50-G-U-M12-4.5OVP-000-000?

    • This sensor is available with various mounting options, including threaded, flanged, and surface-mount configurations.
  10. Are there any special considerations for installing P51-50-G-U-M12-4.5OVP-000-000?

    • Proper sealing, protection from mechanical damage, and adherence to specified installation guidelines are important for optimal performance and longevity of the sensor.