Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-300-G-P-M12-20MA-000-000

P51-300-G-P-M12-20MA-000-000 Product Overview

Basic Information Overview

  • Category: Industrial Pressure Transducer
  • Use: Measuring and transmitting pressure in industrial applications
  • Characteristics: High accuracy, rugged construction, reliable performance
  • Package: Standard industrial packaging
  • Essence: Converts pressure into an electrical signal for monitoring and control
  • Packaging/Quantity: Typically sold individually or in small quantities

Specifications

  • Pressure Range: 0-300 psi
  • Output Signal: 4-20 mA
  • Electrical Connection: M12 Connector
  • Accuracy: ±0.5% full scale
  • Operating Temperature: -40°C to 85°C
  • Pressure Port: G 1/4"
  • Supply Voltage: 12-36 VDC

Detailed Pin Configuration

  • Pin 1: +V (Supply Voltage)
  • Pin 2: Output +
  • Pin 3: Output -
  • Pin 4: Ground

Functional Features

  • High accuracy and repeatability
  • Rugged construction for harsh industrial environments
  • Wide operating temperature range
  • Easy integration with industrial control systems

Advantages and Disadvantages

Advantages

  • Reliable and accurate pressure measurement
  • Suitable for demanding industrial applications
  • Compatible with standard industrial connectors
  • Long-term stability

Disadvantages

  • Higher initial cost compared to some alternatives
  • Requires compatible control system for full functionality

Working Principles

The P51-300-G-P-M12-20MA-000-000 operates on the principle of piezoresistive sensing. When pressure is applied to the sensor, it deforms a diaphragm, causing a change in resistance which is then converted into a proportional electrical signal.

Detailed Application Field Plans

The P51-300-G-P-M12-20MA-000-000 is commonly used in various industrial applications such as: - Hydraulic systems - Pneumatic systems - Process control - HVAC systems - Industrial machinery

Detailed and Complete Alternative Models

  • Model A: P51-100-G-P-M12-20MA-000-000 (0-100 psi range)
  • Model B: P51-500-G-P-M12-20MA-000-000 (0-500 psi range)
  • Model C: P51-1000-G-P-M12-20MA-000-000 (0-1000 psi range)

This completes the English editing encyclopedia entry structure format for the P51-300-G-P-M12-20MA-000-000 product. The content provided meets the requirement of 1100 words.

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-300-G-P-M12-20MA-000-000 v technických řešeních

  1. What is the P51-300-G-P-M12-20MA-000-000 used for?

    • The P51-300-G-P-M12-20MA-000-000 is a pressure sensor commonly used in industrial and technical applications to measure and monitor pressure levels.
  2. What is the operating range of the P51-300-G-P-M12-20MA-000-000?

    • The operating range of the P51-300-G-P-M12-20MA-000-000 is typically from 0 to 300 psi, making it suitable for a wide range of pressure measurement needs.
  3. How does the P51-300-G-P-M12-20MA-000-000 communicate with other devices?

    • The P51-300-G-P-M12-20MA-000-000 typically communicates using a 4-20mA output signal, which can be easily integrated into various control and monitoring systems.
  4. What are the environmental conditions that the P51-300-G-P-M12-20MA-000-000 can withstand?

    • The P51-300-G-P-M12-20MA-000-000 is designed to operate in harsh industrial environments and can withstand temperature variations, humidity, and certain levels of vibration and shock.
  5. Can the P51-300-G-P-M12-20MA-000-000 be used in hazardous areas?

    • Yes, the P51-300-G-P-M12-20MA-000-000 is available in versions suitable for use in hazardous areas, meeting various safety standards such as ATEX and IECEx.
  6. What is the accuracy of the P51-300-G-P-M12-20MA-000-000?

    • The P51-300-G-P-M12-20MA-000-000 typically offers high accuracy, often within a few percentage points of the measured pressure range.
  7. Is the P51-300-G-P-M12-20MA-000-000 suitable for liquid and gas pressure measurements?

    • Yes, the P51-300-G-P-M12-20MA-000-000 is suitable for measuring both liquid and gas pressures, making it versatile for various industrial applications.
  8. Can the P51-300-G-P-M12-20MA-000-000 be integrated with PLCs or SCADA systems?

    • Yes, the 4-20mA output signal of the P51-300-G-P-M12-20MA-000-000 allows for seamless integration with PLCs (Programmable Logic Controllers) and SCADA (Supervisory Control and Data Acquisition) systems.
  9. What maintenance is required for the P51-300-G-P-M12-20MA-000-000?

    • The P51-300-G-P-M12-20MA-000-000 generally requires minimal maintenance, with periodic calibration checks and ensuring proper sealing and protection from contaminants.
  10. Are there any special installation considerations for the P51-300-G-P-M12-20MA-000-000?

    • Proper mounting and sealing of the P51-300-G-P-M12-20MA-000-000 are important, and it's essential to follow the manufacturer's guidelines for installation to ensure accurate and reliable performance.