Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-2000-A-J-M12-20MA-000-000

P51-2000-A-J-M12-20MA-000-000

Product Overview

Category

The P51-2000-A-J-M12-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure readings in industrial settings, providing crucial data for process control and monitoring.

Characteristics

  • High accuracy and reliability
  • Robust construction for harsh industrial environments
  • Compatibility with various media types
  • Easy installation and maintenance

Package

The P51-2000-A-J-M12-20MA-000-000 is typically packaged in a protective casing to ensure safe transportation and storage. The package includes the transmitter unit, necessary connectors, and user manual.

Essence

The essence of this product lies in its ability to accurately measure and transmit pressure data, contributing to efficient and safe industrial operations.

Packaging/Quantity

The product is usually packaged individually and is available in single-unit quantities.

Specifications

  • Pressure Range: 0-2000 psi
  • Output Signal: 4-20 mA
  • Electrical Connection: M12 connector
  • Operating Temperature: -40°C to 85°C
  • Pressure Connection: 1/4" NPT male

Detailed Pin Configuration

The detailed pin configuration of the P51-2000-A-J-M12-20MA-000-000 is as follows: - Pin 1: Power Supply (+) - Pin 2: Power Supply (-) - Pin 3: Signal Output - Pin 4: Not Connected

Functional Features

  • High precision pressure sensing
  • Linear output signal for easy integration with control systems
  • Built-in temperature compensation for accurate readings across varying temperatures
  • Overpressure protection for enhanced durability

Advantages

  • Accurate and reliable pressure measurements
  • Suitable for demanding industrial environments
  • Easy integration with existing control systems
  • Long-term stability and durability

Disadvantages

  • Higher initial cost compared to some lower-end alternatives
  • Requires periodic calibration and maintenance

Working Principles

The P51-2000-A-J-M12-20MA-000-000 operates on the principle of piezoresistive sensing, where changes in pressure cause corresponding changes in the resistance of the sensing element. This change in resistance is then converted into a proportional electrical signal, which is transmitted as the output.

Detailed Application Field Plans

The P51-2000-A-J-M12-20MA-000-000 is well-suited for applications such as: - Hydraulic systems - Pneumatic systems - Industrial machinery - Process control and monitoring

Detailed and Complete Alternative Models

Some alternative models to consider include: - P51-1000-A-J-M12-20MA-000-000 (0-1000 psi range) - P51-3000-A-J-M12-20MA-000-000 (0-3000 psi range) - P51-2000-B-J-M12-20MA-000-000 (with different electrical connection)

In conclusion, the P51-2000-A-J-M12-20MA-000-000 offers high-precision pressure measurement and transmission capabilities, making it an essential component in various industrial applications. Its robust design, functional features, and compatibility with control systems make it a valuable asset for ensuring operational efficiency and safety. While it may have some initial cost and maintenance considerations, its performance and reliability justify its place in industrial settings.

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-2000-A-J-M12-20MA-000-000 v technických řešeních

  1. What is P51-2000-A-J-M12-20MA-000-000?

    • P51-2000-A-J-M12-20MA-000-000 is a pressure transducer used to measure pressure in various technical applications.
  2. What is the operating range of P51-2000-A-J-M12-20MA-000-000?

    • The operating range of P51-2000-A-J-M12-20MA-000-000 is typically from 0 to 2000 psi.
  3. How does P51-2000-A-J-M12-20MA-000-000 communicate with other devices?

    • P51-2000-A-J-M12-20MA-000-000 communicates using a 4-20mA output signal, which is commonly used in industrial automation and control systems.
  4. Can P51-2000-A-J-M12-20MA-000-000 be used in harsh environments?

    • Yes, P51-2000-A-J-M12-20MA-000-000 is designed to withstand harsh environments and is often used in industrial and automotive applications.
  5. What is the accuracy of P51-2000-A-J-M12-20MA-000-000?

    • The accuracy of P51-2000-A-J-M12-20MA-000-000 is typically within ±0.5% of the full scale.
  6. Is P51-2000-A-J-M12-20MA-000-000 suitable for use with corrosive media?

    • Yes, P51-2000-A-J-M12-20MA-000-000 can be configured with materials that are compatible with corrosive media, making it suitable for such applications.
  7. What are the typical applications of P51-2000-A-J-M12-20MA-000-000?

    • Typical applications of P51-2000-A-J-M12-20MA-000-000 include hydraulic systems, process control, and industrial machinery.
  8. Does P51-2000-A-J-M12-20MA-000-000 require calibration?

    • Yes, P51-2000-A-J-M12-20MA-000-000 should be calibrated periodically to ensure accurate measurements.
  9. Can P51-2000-A-J-M12-20MA-000-000 be integrated with PLCs or SCADA systems?

    • Yes, P51-2000-A-J-M12-20MA-000-000 can be easily integrated with PLCs or SCADA systems using its 4-20mA output signal.
  10. What are the environmental specifications of P51-2000-A-J-M12-20MA-000-000?

    • P51-2000-A-J-M12-20MA-000-000 is typically rated for operation within a temperature range of -40°C to 85°C and is designed to meet various industry standards for environmental performance.