Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-200-S-AD-MD-20MA-000-000

P51-200-S-AD-MD-20MA-000-000

Product Overview

Category

The P51-200-S-AD-MD-20MA-000-000 belongs to the category of industrial pressure sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The sensor is typically packaged in a protective casing to ensure durability during transportation and installation.

Essence

The essence of the P51-200-S-AD-MD-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in industrial environments.

Packaging/Quantity

The sensor is usually sold individually, packed securely to prevent damage during shipping.

Specifications

  • Pressure Range: 0-200 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 125°C
  • Media Compatibility: Compatible with a wide range of liquids and gases
  • Accuracy: ±0.5% full scale

Detailed Pin Configuration

The detailed pin configuration of the P51-200-S-AD-MD-20MA-000-000 includes power supply, ground, and output pins, as well as any additional pins for communication or calibration purposes.

Functional Features

  • High precision measurement
  • Compatibility with various industrial media
  • Long-term stability and reliability
  • Compact and rugged design for harsh environments
  • Easy integration into existing systems

Advantages and Disadvantages

Advantages

  • Accurate and reliable pressure measurements
  • Wide operating temperature range
  • Compatibility with different media
  • Robust construction for durability in industrial settings

Disadvantages

  • May require periodic calibration
  • Initial cost may be higher compared to some alternatives

Working Principles

The P51-200-S-AD-MD-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, typically using strain gauge technology. This signal is then conditioned and converted to a standardized output, such as 4-20 mA, for easy integration into control systems.

Detailed Application Field Plans

The P51-200-S-AD-MD-20MA-000-000 is suitable for a wide range of industrial applications, including: - Hydraulic systems - Process control - HVAC systems - Industrial machinery - Pneumatic systems

Detailed and Complete Alternative Models

Some alternative models to the P51-200-S-AD-MD-20MA-000-000 include: - P51-100-S-AD-MD-20MA-000-000 - P51-300-S-AD-MD-20MA-000-000 - P51-200-S-AD-MD-10MA-000-000

This completes the English editing encyclopedia entry structure for the P51-200-S-AD-MD-20MA-000-000, providing comprehensive information about its category, use, characteristics, specifications, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-200-S-AD-MD-20MA-000-000 v technických řešeních

  1. What is the application of P51-200-S-AD-MD-20MA-000-000?

    • P51-200-S-AD-MD-20MA-000-000 is a pressure transducer commonly used in industrial and commercial applications to measure and monitor pressure in various systems.
  2. What are the typical industries that use P51-200-S-AD-MD-20MA-000-000?

    • This pressure transducer is commonly used in HVAC systems, hydraulic systems, pneumatic systems, process control, and industrial automation.
  3. What is the pressure range of P51-200-S-AD-MD-20MA-000-000?

    • The pressure range of P51-200-S-AD-MD-20MA-000-000 can vary, but it is typically used for measuring pressures ranging from 0 to 200 psi.
  4. What type of output signal does P51-200-S-AD-MD-20MA-000-000 provide?

    • P51-200-S-AD-MD-20MA-000-000 provides a 4-20 mA output signal, which is commonly used in industrial control systems.
  5. Is P51-200-S-AD-MD-20MA-000-000 suitable for outdoor applications?

    • Yes, P51-200-S-AD-MD-20MA-000-000 is often designed to be suitable for outdoor applications, with appropriate environmental protection and sealing.
  6. Can P51-200-S-AD-MD-20MA-000-000 be used in high-temperature environments?

    • Some models of P51-200-S-AD-MD-20MA-000-000 are designed to withstand high temperatures, but it's important to check the specific model's specifications for temperature limits.
  7. What is the accuracy of P51-200-S-AD-MD-20MA-000-000?

    • The accuracy of P51-200-S-AD-MD-20MA-000-000 can vary, but it is typically specified as a percentage of full scale, such as ±0.5% FS.
  8. Does P51-200-S-AD-MD-20MA-000-000 require calibration?

    • Yes, like most pressure transducers, P51-200-S-AD-MD-20MA-000-000 requires periodic calibration to ensure accurate measurements.
  9. Can P51-200-S-AD-MD-20MA-000-000 be integrated with PLCs or SCADA systems?

    • Yes, P51-200-S-AD-MD-20MA-000-000 can be integrated with PLCs or SCADA systems using its 4-20 mA output signal for monitoring and control.
  10. Are there any special installation considerations for P51-200-S-AD-MD-20MA-000-000?

    • It's important to follow the manufacturer's guidelines for proper installation, including mounting orientation, electrical connections, and environmental considerations.