Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-100-G-T-MD-20MA-000-000

P51-100-G-T-MD-20MA-000-000

Category: Electronic Component

Use: This product is a precision pressure sensor designed for use in various industrial and commercial applications. It is commonly used to measure and monitor pressure in fluid systems.

Characteristics: The P51-100-G-T-MD-20MA-000-000 features high accuracy, reliability, and stability. It is designed to operate effectively in harsh environments and can withstand extreme temperatures and pressures. The sensor is compact and lightweight, making it suitable for integration into different systems and equipment.

Package: The sensor is typically housed in a durable and protective casing to ensure its longevity and performance. It is available in various package options to accommodate different installation requirements.

Essence: The essence of the P51-100-G-T-MD-20MA-000-000 lies in its ability to provide precise and consistent pressure measurements, contributing to the efficient operation and safety of the systems it is integrated into.

Packaging/Quantity: The sensor is usually supplied in individual packaging to prevent damage during transportation and storage. The quantity per package may vary based on the supplier and customer's specific needs.

Specifications

  • Pressure Range: 0-100 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 125°C
  • Supply Voltage: 10-30 VDC
  • Accuracy: ±0.5% FS
  • Electrical Connection: M12 Connector

Detailed Pin Configuration

The P51-100-G-T-MD-20MA-000-000 features a standard pin configuration with clearly labeled pins for power supply, output signal, and ground connection. The pinout ensures easy and accurate installation and integration into different systems.

Functional Features

  • High Precision: The sensor provides accurate and reliable pressure measurements, ensuring precise monitoring and control of fluid systems.
  • Robust Design: Its robust construction allows it to withstand challenging environmental conditions, making it suitable for a wide range of applications.
  • Easy Integration: The sensor's compact design and standardized pin configuration facilitate seamless integration into diverse systems and equipment.

Advantages and Disadvantages

Advantages - High accuracy and reliability - Wide operating temperature range - Compact and lightweight design - Suitable for harsh environments

Disadvantages - Limited pressure range compared to some alternative models - Dependency on external power supply

Working Principles

The P51-100-G-T-MD-20MA-000-000 operates on the principle of piezoresistive sensing, where changes in pressure cause deformation in the sensor's diaphragm, leading to a corresponding change in electrical resistance. This change is then converted into a proportional 4-20 mA output signal, providing an accurate representation of the applied pressure.

Detailed Application Field Plans

The P51-100-G-T-MD-20MA-000-000 is widely used in industrial automation, hydraulic systems, pneumatic systems, and process control applications. It is particularly suitable for pressure monitoring in manufacturing processes, HVAC systems, and automotive applications.

Detailed and Complete Alternative Models

  • Model A: P51-50-G-T-MD-20MA-000-000 (Pressure Range: 0-50 psi)
  • Model B: P51-200-G-T-MD-20MA-000-000 (Pressure Range: 0-200 psi)
  • Model C: P51-100-G-T-MD-10V-000-000 (Output: 0-10 VDC)

These alternative models offer varying pressure ranges and output options to cater to different application requirements.

This comprehensive entry provides a detailed overview of the P51-100-G-T-MD-20MA-000-000, covering its specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-100-G-T-MD-20MA-000-000 v technických řešeních

  1. What is the P51-100-G-T-MD-20MA-000-000 sensor used for?

    • The P51-100-G-T-MD-20MA-000-000 sensor is a pressure transducer commonly used to measure and monitor pressure in various technical applications.
  2. What is the operating range of the P51-100-G-T-MD-20MA-000-000 sensor?

    • The operating range of the P51-100-G-T-MD-20MA-000-000 sensor is typically from 0 to 100 psi, making it suitable for a wide range of pressure measurement needs.
  3. What are the output options for the P51-100-G-T-MD-20MA-000-000 sensor?

    • The P51-100-G-T-MD-20MA-000-000 sensor typically provides a 4-20mA output signal, which is commonly used in industrial automation and control systems.
  4. Is the P51-100-G-T-MD-20MA-000-000 sensor suitable for use in harsh environments?

    • Yes, the P51-100-G-T-MD-20MA-000-000 sensor is designed to withstand harsh environmental conditions, including high vibration and extreme temperatures.
  5. Can the P51-100-G-T-MD-20MA-000-000 sensor be used for both liquid and gas pressure measurement?

    • Yes, the P51-100-G-T-MD-20MA-000-000 sensor is suitable for measuring both liquid and gas pressures, making it versatile for different applications.
  6. What is the accuracy of the P51-100-G-T-MD-20MA-000-000 sensor?

    • The P51-100-G-T-MD-20MA-000-000 sensor typically offers high accuracy, often within ±0.25% of full scale, ensuring precise pressure measurements.
  7. Does the P51-100-G-T-MD-20MA-000-000 sensor require calibration?

    • Yes, like most sensors, the P51-100-G-T-MD-20MA-000-000 sensor should be calibrated periodically to maintain its accuracy and performance.
  8. What are the typical applications for the P51-100-G-T-MD-20MA-000-000 sensor?

    • Typical applications for the P51-100-G-T-MD-20MA-000-000 sensor include hydraulic systems, pneumatic systems, industrial machinery, and process control.
  9. Is the P51-100-G-T-MD-20MA-000-000 sensor compatible with standard industrial interfaces?

    • Yes, the P51-100-G-T-MD-20MA-000-000 sensor is often compatible with standard industrial interfaces such as PLCs, SCADA systems, and data acquisition equipment.
  10. What are the installation considerations for the P51-100-G-T-MD-20MA-000-000 sensor?

    • When installing the P51-100-G-T-MD-20MA-000-000 sensor, it's important to ensure proper sealing, mounting orientation, and electrical connections to optimize its performance and longevity.