Product Overview

Category

The P51-100-G-AD-M12-4.5OVP-000-000 belongs to the category of pressure sensors.

Use

This product is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The P51-100-G-AD-M12-4.5OVP-000-000 is typically packaged individually in protective casing to ensure safe transportation and storage.

Essence

The essence of this product lies in its ability to provide precise and reliable pressure measurements in challenging environments.

Packaging/Quantity

Each unit is packaged individually, and the quantity may vary based on the specific order requirements.

Specifications

  • Model: P51-100-G-AD-M12-4.5OVP-000-000
  • Pressure Range: 0-100 psi
  • Output: Analog (4-20mA)
  • Overpressure: 4.5 times the rated pressure
  • Electrical Connection: M12 Connector
  • Operating Temperature: -40°C to 125°C
  • Media Compatibility: Compatible with a wide range of liquids and gases

Detailed Pin Configuration

The detailed pin configuration for the P51-100-G-AD-M12-4.5OVP-000-000 is as follows: - Pin 1: Power Supply (+) - Pin 2: Power Supply (-) - Pin 3: Analog Output - Pin 4: Not Connected

Functional Features

  • Accurate pressure measurement
  • Overpressure protection
  • Easy integration with control systems
  • Compact and rugged design
  • Long-term reliability

Advantages

  • High accuracy and precision
  • Wide operating temperature range
  • Robust construction for durability
  • Compatibility with various media
  • Overpressure protection ensures product longevity

Disadvantages

  • Limited to specific pressure range
  • Requires compatible M12 connector for installation
  • May require additional signal conditioning for certain applications

Working Principles

The P51-100-G-AD-M12-4.5OVP-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted as an analog output for further processing and monitoring.

Detailed Application Field Plans

The P51-100-G-AD-M12-4.5OVP-000-000 is suitable for a wide range of applications including: - Industrial automation - Hydraulic systems - Pneumatic systems - Process control - HVAC systems - Aerospace and automotive industries

Detailed and Complete Alternative Models

  • P51-50-G-AD-M12-4.5OVP-000-000: 0-50 psi pressure range
  • P51-200-G-AD-M12-4.5OVP-000-000: 0-200 psi pressure range
  • P51-100-G-AD-M12-6.0OVP-000-000: 0-100 psi pressure range with 6.0 times overpressure protection

In conclusion, the P51-100-G-AD-M12-4.5OVP-000-000 pressure sensor offers high accuracy, robustness, and reliability, making it an ideal choice for various industrial applications requiring precise pressure monitoring and control.

[Word Count: 498]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-100-G-AD-M12-4.5OVP-000-000 v technických řešeních

  1. What is the application of P51-100-G-AD-M12-4.5OVP-000-000?

    • The P51-100-G-AD-M12-4.5OVP-000-000 is commonly used as a pressure transducer in various technical solutions.
  2. How does P51-100-G-AD-M12-4.5OVP-000-000 work?

    • This transducer converts pressure into an electrical signal, providing accurate and reliable pressure measurements.
  3. What are the typical industries that use P51-100-G-AD-M12-4.5OVP-000-000?

    • Industries such as automotive, aerospace, industrial manufacturing, and HVAC often utilize this transducer for pressure monitoring and control.
  4. What is the pressure range of P51-100-G-AD-M12-4.5OVP-000-000?

    • The pressure range of this transducer is 0 to 100 psi, making it suitable for a wide range of applications.
  5. Can P51-100-G-AD-M12-4.5OVP-000-000 be used in harsh environments?

    • Yes, this transducer is designed to withstand harsh environmental conditions, including temperature variations and mechanical stress.
  6. What output signals does P51-100-G-AD-M12-4.5OVP-000-000 provide?

    • It typically provides analog voltage output signals, making it compatible with various control and monitoring systems.
  7. Is P51-100-G-AD-M12-4.5OVP-000-000 easy to install?

    • Yes, it comes with standard M12 connectors and mounting options, facilitating easy installation in different technical solutions.
  8. Does P51-100-G-AD-M12-4.5OVP-000-000 require calibration?

    • Periodic calibration may be necessary to ensure accurate and consistent pressure measurements over time.
  9. Can P51-100-G-AD-M12-4.5OVP-000-000 be integrated with digital control systems?

    • Yes, it can be integrated with digital control systems through appropriate signal conditioning and interface modules.
  10. Are there any special considerations for maintenance of P51-100-G-AD-M12-4.5OVP-000-000?

    • Regular inspection for damage, proper sealing, and cleanliness is recommended to maintain the performance and longevity of the transducer.