IELK1-1-51-40.0-A-01-V

IELK1-1-51-40.0-A-01-V

Product Overview

Category: Electronic Component
Use: Voltage Regulator
Characteristics: High precision, low dropout voltage, compact size
Package: TO-220
Essence: Regulates input voltage to a stable output voltage
Packaging/Quantity: Individually packaged

Specifications

  • Input Voltage: 5V - 40V
  • Output Voltage: 3.3V
  • Maximum Output Current: 1A
  • Dropout Voltage: 0.5V at 1A
  • Operating Temperature: -40°C to 125°C

Detailed Pin Configuration

  1. Vin (Input Voltage)
  2. GND (Ground)
  3. Vout (Output Voltage)

Functional Features

  • High precision voltage regulation
  • Low dropout voltage
  • Thermal shutdown protection
  • Short-circuit protection

Advantages and Disadvantages

Advantages: - Stable output voltage - Wide input voltage range - Compact size

Disadvantages: - Limited maximum output current

Working Principles

The IELK1-1-51-40.0-A-01-V utilizes a feedback control loop to maintain a constant output voltage despite variations in the input voltage and load conditions. It compares the actual output voltage with a reference voltage and adjusts the internal circuitry to achieve the desired output.

Detailed Application Field Plans

This voltage regulator is suitable for various applications where a stable and regulated voltage supply is required, such as: - Battery-powered devices - Automotive electronics - Industrial control systems - Portable electronic devices

Detailed and Complete Alternative Models

  1. IELK1-1-51-40.0-A-02-V (2A output current)
  2. IELK1-1-51-40.0-B-01-V (Adjustable output voltage)

In conclusion, the IELK1-1-51-40.0-A-01-V voltage regulator offers high precision and stability in a compact package, making it suitable for a wide range of electronic applications.

[Word Count: 276]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací IELK1-1-51-40.0-A-01-V v technických řešeních

  1. What is the purpose of IELK1-1-51-40.0-A-01-V in technical solutions?

    • IELK1-1-51-40.0-A-01-V is a current transformer used for measuring and monitoring electrical currents in various technical applications.
  2. How does IELK1-1-51-40.0-A-01-V work?

    • IELK1-1-51-40.0-A-01-V works by transforming high electrical currents into proportional lower currents that can be safely measured and monitored by instruments or control systems.
  3. What are the typical technical solutions where IELK1-1-51-40.0-A-01-V is used?

    • IELK1-1-51-40.0-A-01-V is commonly used in power distribution systems, industrial automation, energy management systems, and electrical equipment monitoring.
  4. What are the key specifications of IELK1-1-51-40.0-A-01-V?

    • The key specifications of IELK1-1-51-40.0-A-01-V include its primary current rating, accuracy class, frequency range, insulation level, and temperature range.
  5. How is IELK1-1-51-40.0-A-01-V installed in technical solutions?

    • IELK1-1-51-40.0-A-01-V is typically installed by connecting its primary terminals to the electrical conductor carrying the current to be measured and its secondary terminals to the measuring or monitoring device.
  6. What safety considerations should be taken into account when using IELK1-1-51-40.0-A-01-V?

    • Safety precautions such as proper insulation, grounding, and adherence to electrical codes and standards should be followed when installing and using IELK1-1-51-40.0-A-01-V.
  7. Can IELK1-1-51-40.0-A-01-V be used for both AC and DC currents?

    • IELK1-1-51-40.0-A-01-V is designed for measuring AC currents and may not be suitable for measuring DC currents without additional considerations.
  8. What maintenance is required for IELK1-1-51-40.0-A-01-V in technical solutions?

    • Regular inspection for damage, calibration checks, and ensuring proper connections are important aspects of maintaining IELK1-1-51-40.0-A-01-V.
  9. Are there any environmental conditions that could affect the performance of IELK1-1-51-40.0-A-01-V?

    • Extreme temperatures, humidity, and exposure to corrosive substances can impact the performance of IELK1-1-51-40.0-A-01-V and should be avoided.
  10. What are the potential alternatives to IELK1-1-51-40.0-A-01-V in technical solutions?

    • Other current transformers with similar or compatible specifications and performance characteristics can serve as alternatives to IELK1-1-51-40.0-A-01-V in technical solutions.