The MAX803SEXR+T10 has three pins in the SOT-23-3 package: 1. GND: Ground connection 2. RESET: Reset output signal 3. VCC: Supply voltage input
The MAX803SEXR+T10 operates by comparing the supply voltage with a reference voltage set by the chosen threshold option. When the supply voltage drops below the threshold, the reset output is asserted, indicating a power failure or unstable voltage condition. The manual reset input allows for an external signal to override the voltage monitoring function and assert the reset signal. The watchdog timer ensures that the system is responsive by periodically resetting it if no activity is detected within the timeout period. The power-on reset delay provides a stable power supply before releasing the reset signal during system startup.
The MAX803SEXR+T10 is commonly used in various applications where reliable voltage monitoring and reset functionality are required. Some potential application fields include: - Microcontrollers and digital systems - Embedded systems - Industrial automation - Power management systems - Battery-powered devices - IoT devices
(Note: The alternative models listed above are just a few examples and not an exhaustive list.)
Word Count: 431
Sure! Here are 10 common questions and answers related to the application of MAX803SEXR+T10 in technical solutions:
Question: What is the purpose of MAX803SEXR+T10?
Answer: MAX803SEXR+T10 is a voltage monitor and reset IC that ensures proper system operation by monitoring the power supply voltage and generating a reset signal when the voltage falls below a specified threshold.
Question: What is the operating voltage range of MAX803SEXR+T10?
Answer: The operating voltage range of MAX803SEXR+T10 is typically between 1.6V and 5.5V.
Question: How does MAX803SEXR+T10 generate a reset signal?
Answer: MAX803SEXR+T10 generates a reset signal by pulling the RESET output pin low when the monitored voltage falls below the specified threshold.
Question: Can I adjust the threshold voltage for generating a reset signal?
Answer: No, the threshold voltage for generating a reset signal is fixed and cannot be adjusted in MAX803SEXR+T10.
Question: What is the typical reset timeout period of MAX803SEXR+T10?
Answer: The typical reset timeout period of MAX803SEXR+T10 is 140ms.
Question: Can I use MAX803SEXR+T10 in battery-powered applications?
Answer: Yes, MAX803SEXR+T10 can be used in battery-powered applications as it operates within a wide voltage range and has low quiescent current consumption.
Question: Does MAX803SEXR+T10 have any built-in hysteresis?
Answer: Yes, MAX803SEXR+T10 has a built-in hysteresis of typically 50mV, which helps to prevent false reset signals due to voltage fluctuations.
Question: What is the maximum supply current of MAX803SEXR+T10?
Answer: The maximum supply current of MAX803SEXR+T10 is typically 7µA.
Question: Can I use MAX803SEXR+T10 in automotive applications?
Answer: Yes, MAX803SEXR+T10 is suitable for automotive applications as it meets the AEC-Q100 automotive qualification standards.
Question: Is MAX803SEXR+T10 available in different package options?
Answer: Yes, MAX803SEXR+T10 is available in a variety of package options, including SOT23-3 and SC70-3.
Please note that these answers are based on general information about MAX803SEXR+T10 and may vary depending on specific application requirements. It is always recommended to refer to the datasheet and consult with the manufacturer for accurate and detailed information.