Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
MAX6363PUT26-T

MAX6363PUT26-T

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Voltage Supervisor
  • Characteristics: Low-power, Precision, Reset Output
  • Package: SOT23-6
  • Essence: Monitors and controls voltage levels in electronic systems
  • Packaging/Quantity: Tape and Reel, 3000 units per reel

Specifications

  • Supply Voltage Range: 1.5V to 5.5V
  • Reset Threshold Voltage: 2.63V
  • Reset Timeout Period: 140ms
  • Quiescent Current: 1.5µA (typical)
  • Operating Temperature Range: -40°C to +85°C

Detailed Pin Configuration

The MAX6363PUT26-T has a total of 6 pins:

  1. GND: Ground connection
  2. RESET: Active-low reset output
  3. MR: Manual reset input
  4. VCC: Positive supply voltage
  5. TH: Threshold voltage adjustment pin
  6. NC: No connection

Functional Features

  • Monitors the supply voltage and generates a reset signal when it falls below the threshold voltage.
  • Provides a manual reset input for external control.
  • Offers a precision threshold voltage with low temperature drift.
  • Consumes very low quiescent current, making it suitable for battery-powered applications.
  • Includes a built-in power-on reset delay to ensure stable operation during power-up.

Advantages and Disadvantages

Advantages: - Precise monitoring of voltage levels - Low power consumption - Small package size - Wide operating temperature range

Disadvantages: - Limited number of pins for additional functionality - Fixed reset timeout period

Working Principles

The MAX6363PUT26-T operates by comparing the supply voltage with the threshold voltage set by the TH pin. When the supply voltage drops below the threshold, the reset output is activated, indicating a power failure or an out-of-range condition. The reset output remains active until the supply voltage rises above the threshold and the reset timeout period elapses.

Detailed Application Field Plans

The MAX6363PUT26-T is commonly used in various electronic systems where reliable voltage monitoring is crucial. Some application fields include:

  1. Microcontrollers: Ensures proper system initialization and prevents erratic behavior during power-up.
  2. Industrial Control Systems: Monitors power supply integrity to prevent damage to sensitive equipment.
  3. Automotive Electronics: Protects critical components from voltage fluctuations and ensures safe operation.
  4. Battery-Powered Devices: Maximizes battery life by providing accurate low-battery detection and shutdown control.

Detailed and Complete Alternative Models

  1. MAX6365PUT26-T: Similar to MAX6363PUT26-T but with a higher reset threshold voltage of 3.08V.
  2. MAX6367PUT26-T: Offers adjustable threshold voltage through an external resistor.
  3. MAX6369PUT26-T: Provides a longer reset timeout period of 280ms for applications requiring extended stabilization time.

These alternative models offer flexibility in voltage monitoring based on specific application requirements.

Word count: 346 words

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací MAX6363PUT26-T v technických řešeních

Sure! Here are 10 common questions and answers related to the application of MAX6363PUT26-T in technical solutions:

  1. Q: What is the MAX6363PUT26-T? A: The MAX6363PUT26-T is a voltage monitor and reset circuit that provides power supply monitoring and reset generation for microcontrollers, DSPs, and other digital systems.

  2. Q: What is the operating voltage range of MAX6363PUT26-T? A: The operating voltage range of MAX6363PUT26-T is from 1.6V to 5.5V.

  3. Q: How does the MAX6363PUT26-T monitor the power supply? A: The MAX6363PUT26-T monitors the power supply by comparing the monitored voltage with a preset threshold voltage.

  4. Q: Can I adjust the threshold voltage of MAX6363PUT26-T? A: No, the threshold voltage of MAX6363PUT26-T is fixed at 2.63V.

  5. Q: What happens when the monitored voltage drops below the threshold voltage? A: When the monitored voltage drops below the threshold voltage, the MAX6363PUT26-T asserts a reset signal to the microcontroller or digital system.

  6. Q: Does MAX6363PUT26-T have a manual reset input? A: Yes, MAX6363PUT26-T has a manual reset input (MR) that can be used to assert a reset signal externally.

  7. Q: What is the typical reset timeout period of MAX6363PUT26-T? A: The typical reset timeout period of MAX6363PUT26-T is 140ms.

  8. Q: Can I use MAX6363PUT26-T in battery-powered applications? A: Yes, MAX6363PUT26-T can be used in battery-powered applications as it operates within a wide voltage range and has low quiescent current.

  9. Q: Does MAX6363PUT26-T have an open-drain reset output? A: Yes, MAX6363PUT26-T has an open-drain reset output (RESET) that can be pulled up externally.

  10. Q: What is the package type of MAX6363PUT26-T? A: MAX6363PUT26-T is available in a 6-pin SOT23 package.

Please note that these answers are based on general information about the MAX6363PUT26-T and may vary depending on specific application requirements.